Dave asked ... Repair kettle lid?    |    Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Click here to ask your question

vaillant boiler?

the red light has come on and f75 no heating please advise vaillant ecotec
linda, January 2011
I have had the PCB changed last week on my Combi Thermo plus boiler, from that time my thermostat is not signalling the right temperature. I set it on 23 degrees and it stays oon 19 to 20.5. It does not go higher.

bibi, January 2011
F75 points to a few possible problems, hopefully for you not too serious.

There are four buttons under the display, the top left one resets the boiler, while the boiler is going through its start up check, press the bottom left ( - ) button, this will tell you on the display how much pressure is in the boiler (measured in bars), if it's below 1.0, top it up until it reaches between 1 & 1.5bar Just keep pressing the minus button to see the pressure.

If that doesn't sort it and F75 re-appears, you will need to call someone in, as either the pressure sensor or pump will be faulty.

Carefree, January 2011