3 hours ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

potterton puma 80?

hi i have a potterton puma 80 combi boiler, the pressure light comes on after about 8 hours of intermittent use and needs re-filling and will then work for another 8 hours befor it needs re-filling again, anyone any ideas thanks
chris, February 2011
You have a leak on the system somewhere.
When using the heating, keep an eye on the pressure on the guage, if it rises significantly (towards or past the red point), the system will most likely be losing pressure through the prv, this would mean the expansion vessel needs recharging/replacing.

Carefree, February 2011