John asked ... Scantronix 9450 box stuck shut?    |    Pekaye asked ... Clutch Cable change?    |    Richard asked ... Mountfield SP414 mower, revs too high?    |    Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Click here to ask your question

valliant eco plus 837 boiler ?

hi

i have a vaillant eco plus 837 boiler , and recently had a small pipe change for shower head to downstairs bathroom. since then i have intermittent hot/cold water central heating seems to be working fine. pressure seems fine. no fault code display either. ive read the manual several times but nothing obvious with this kind of fault. i have also checked for any leaking pipes nothing out of the ordinary. any assistance would be much appreciated?
ian king, March 2011
hot water is working but the heating will not come on

helen, November 2013
When turning on a HW tap start by pressing the 'i' button under the display, the boiler should run through the sequence s.10,11, 13 then finally s.14, also as soon as the tap is opened. The tap symbol should be in the display window. s.14 should be displayed all the time the tap is open and the flame & tap symbols should be on constantly.

Press 'i' again to return to the main display, the temperature on the boiler will steadily rise until it reaches a peak point dependant on HW selection temp, the boiler should now be modulating but the flame should remain constantly on. The CH flow pipe, should remain cold.

This would indicate 'normal operation'

I hope this helps to at least establish that your boiler is operating correctly, if it is deviating from the above, please ask here again.

Carefree, March 2011
link Click here to see other fixes for Vaillant eco plus 837.