Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Roberta asked ... DW5080?    |    Dave asked ... Toilet Push Button not flushing properly?    |    Click here to ask your question

no spark when attempting to ignite baxi boiler?

No spark when trying to ignite baxi boiler, any ideas anyone?
ria, March 2011
the ignition cable (2m white cable) burned out! it happened to me""" 1/ remove the boiler cover. 2/ trace the white cable to the ignitor, you will find that the connection is burned out. 3/ pull out the connectior and re-do the joint. 4/ make sure that the cable will not TOUCH the boiler cover otherwise it bill short arcoss and frame..cover the white cable with a heat resistant sleave, double the sleave to connector?

T. Ellul, March 2011
which boiler ??

brian, March 2011