Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

Grant Euroflame 70/90 oil boiler ?

Boiler appears to be igniting etc. Boiler flu gets hot but no central heating. Has a Grundflos pump linked so the pump could be the problem. Boiler only fires central heating system
John R, March 2011
Can you hear the pump working? unscrew the silver screw in the front face of the pump (a little water will dribble out) look inside you should be able to see the shaft inside rotating replace screw afterwards

even if the pump is rotating it can be that the impellor (fan) has dropped off of the motor shaft so nothing is happening - are the pipes to & from the boiler getting hot? are all the Radiator valves open? are the pump valves open?

However it does sound like the pump is at fault!

www.elanar.co.uk, March 2011