HT asked ... Radio code Philips 22RC200/35?    |    Roberta asked ... DW5080?    |    Dave asked ... Toilet Push Button not flushing properly?    |    Dave asked ... Repair kettle lid?    |    Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Click here to ask your question

Worcester 28CDI Boiler Pressure?

Help !
The Boiler was accidentally overfilled to 3 Bar.
The inlet valve is shut off but every time I bleed a radiator the pressure drops to around 2.5bar but then instantly rises again to 3bar as soon as I stop bleeding it. It's as if it's directly connected to the mains. There is slight drip from the overflow but not much.

How do I drop the pressure back to 1bar ?

Thanks in advance for any help.
Colin P:, March 2011
If the filling key is removed, the only place that mains water can mix with CH water is the domestic heat exchanger, quite common on the CDI

Change the DHE, also the prv may need changing too.

Carefree, March 2011
link Click here to see other fixes for Worcester.