Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Sharma asked ... Replacing pin for belt guard Ranch King Pro 14AT818H205?    |    Click here to ask your question

ferolli falcon startup prob?

hi got a ferolli falcon 25kw combi power light and heating light on when no demand and does'nt fire up when demand for water phoned ferolli and said was ch /dhw sensors replaced them and did dry test and was same phoned again and said it must be pcb changed that and is no change any help will do
andy win, March 2011
the water pressure switch on this boiler has a nasty tendency to clog up which would stop boiler firing
is LED 5 flashing? [low water pressure]
but pressure gauge reads ok?
if your confident enough its possible to clear blockage on water pressure sensor provided you follow the boiler manual instructions for removal of WPS to the letter
involves draining boiler,electrically isolating, breaking water connections, cleaning defective parts, refitting, repressurizing, testing for leaks, power on, checking boiler works
if any of this frightens you
best get professional help

manwithnoname, May 2011
link Click here to see other fixes for Ferroli Falcon 25kw.