1 hour ago Tom asked ... Service manual for Lawnflite 908LA?    |    John asked ... Scantronics 9450 box stuck shut?    |    Pekaye asked ... Clutch Cable change?    |    Richard asked ... Mountfield SP414 mower, revs too high?    |    Don asked ... Find the charger or how to convert the battery?    |    Click here to ask your question

vokera maxin 24e?

The gas keeps going out when i try to heat the water then it will ignite then go out then reignite then go out
lee owens, June 2011
hi lee, this is a discontinued boiler so i assume fairly old. the domestic hot cycling as it is, is due to the flow through the heat exchanger being insufficient and making boiler overheat and cut out on overheat thermostat. It then cools down and relights. This could be due to limescale or a dirty heat exchanger. If it works ok on heating its probably just the domestic hot water heat exchanger. or the diverter valve. Either way it needs cleaning or replacing.

johnokent, June 2011