2 hours ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

How can I fix my baxi solo 2 60PF boiler?

When I switch on my central heating or hot water, the 'fan on' and 'pilot on' come on but the boiler does not come on. I have been told it may be the gas valve that needs replaced. Any help would be greatly appreciated. Many thanks.
Scott, September 2006
If your pilot has not lit then it will probably be the pilot solenoid
situated on the left hand side.if your any good test to see if you get 240 volts on N&L with a multi tester.these solenoids can be removed from the whole valve and will cost less.

gas boiler service nottingham, September 2006
COULD BE GAS PRESSURE, VALVE,ELECTRONIC START, PCB BOARD. NEEDS TO BE TESTED WITH A ELECTRICS TESTER.

HI-SPEC PLUMBING, September 2006