Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Sharma asked ... Replacing pin for belt guard Ranch King Pro 14AT818H205?    |    Click here to ask your question

baxi 105e safety valve opening,too much pressure?

central heating on, pressure increase to over 2.5bar causing relief valve to open,Is the safety electrical swiches faulty?
gaz-t, September 2011
checked pressure in expansion vessel this was very low, increased pressure as requested boiler working as it should per manual.thank you.

gaz t, November 2011
Your boiler expension vessel faulty, try fill air to 0.9 bar and see if improve ot fit another one of 24 litre expension vessel on any heating pipe , can be fitted any where

k, September 2011