Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    John asked ... How can I mend my binatone veva 1210 handset?    |    Kurt asked ... How can i mend my Aiwa HV-FX7700K?    |    Laetitia asked ... Toyota overlocker model 3400 D?    |    Click here to ask your question

How can I fill my Vaillant 824E turbomax with water?

One of the rads was cold so I undid the bleed valve but not realising I have drained the boiler which I did not know at the time was not self filling. Now I cannot see how to fill it up.
ron, October 2006
Under the boiler to the right hand side there should be a small charging key. if not as you look up at the underside you will see two small silver boxes,with large flat blade screws open both of them and the boiler will start to fill. Charge to 1.0 / 1.5 Bar when cold when filled return both screws to the first position.