Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Click here to ask your question

my ariston e combi boiler will not light?

i have changed the fuse on the plug and pressed the on/off and reset switch but it is dead
gill, May 2012
ariston e combi
GCN 47-116-6?
when you say the boiler is dead do you mean no LEDs light up as normal?
or do you mean the boiler LEDs are lit but the boiler doesnt do anything?
if no electrical power to boiler i would check to see if you are getting power to the fused spur first
if NO
then check electrical consumer unit to see if any MCBs have tripped
if YES
then check to see if you are getting power to terminal block on boiler
if YES
check PCB fuse

if LEDs are lit/flashing & the boiler is locked out
depending on which sequence of LEDs are lit its possible to deduce which component might be faulty

need more info before i can proceed

manwithnoname, May 2012
Change 1.2amp fuse to PCB some have two than press reset button

ltd, May 2012
link Click here to see other fixes for Ariston.