Glow-worm space saver 38 50 & 75?

Hopefully a simple question. Does anyone have instructions on how to relight the boilers, Glow-worm space saver 38 50 & 75. I believe the proceedure is the same.
Paul, October 2006


done
My thermo coupler keeps burning out, can i reduce the ferocity of the flame of the pilot on a spacesaver 38 50 75

Steve, November 2015
theres no power going to my timer switch

charles boyle, November 2010
why aren't my radiators warm, gloworm space saver 38 pilot light lit, ignites at increasing temperatures but then goes out after a few minutes...
got a young baby, no DIY man and broke after christmas...any help much appreciated

mj, December 2009
three brown wireing and one green where do they go from the boiler to the swich

chaman lal, September 2009
glowworm space saver 38

chaman lal, September 2009
Instructions are on inside of the base plate.

Turn switch to pilot position, hold in and press piezo button until pilot lights. After 30 second release the button.
Turn switch to ON position. Boiler should ignite. Check for AC power being on if you have a problem.

Mike, January 2007
link Click here to see other fixes for Glow-Worm.