2 hours ago Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

ravenheat combi rsf 82et?

can above boilers pressure vessel be re pressurised.
if so what pressure is required.
also how do you do it.
mike, December 2012
its quite simple drain the heating water out the boiler. then get a car pump (foot pump, bicycle pump with a pressure gauge). then attach the nozzle (same as a car tyre valve) to the red tank and inflate it to 1.5bar. then just fill the boiler back up to pressure. if u dont know how to drain the boiler just drain the rads to 0 pressure but be carefull when inflating the tank it causes more water to be pushed out

kash, December 2012