David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    John asked ... How can I mend my binatone veva 1210 handset?    |    Click here to ask your question

How to increase air supply to Riello RDB Burner?

I have visible smoke coming from flue when the boiler starts up. What does this mean! The Boiler and Burner were installed only last Sept. I am not able to contact the installer at present. The boiler is a Grant 50/90 boiler-house model. I would really appreciate some advice
John, January 2013
when you say smoke, is it white or black?
if its white, this is correct and is condensing steam.
if its black, the combustion settings are way off and need a qualified oftec service engineer to set the burner up with a flue gas analser.
the air screw is on the right hand side of burner, a 3mm allen screw,
but if you twiddle this without the correct training and equipment you will risk melting the blast tube and rendering the boiler scrap.

mark, February 2013
link Click here to see other fixes for Riello.