David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    John asked ... How can I mend my binatone veva 1210 handset?    |    Click here to ask your question

Baxi Solo 3 PFL 50 gas boiler - Pilot light keeps turning off?

This just started tonight — Baxi Solo 3 PFL 50 gas boiler was running fine but then we noticed the radiators getting cold. Looking at the boiler all the lights were on bar the burner light and the blue pilot flame was out. The fans were running as well! Then after about 15 minutes the blue flame came back on but only for about a minute!

This went on all night until the boiler went off at the timer!

Would this be the thermostat or something else?
Peter O, November 2013
could be two things ie new pcb board .or air pressure switch .try pcb board first as most likely

llewellyn, November 2013
link Click here to see other fixes for Baxi Solo 3.