3 hours ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

ferroli f 28 losing pressure?

hi, my boiler is losing water at an alarming rate...i've checked all under floor pipework, nothing, bone dry. no water around the boiler at all.

i shut off the feed and return valves to the radiators, turned the boiler off completely, topped the boiler up to just above 1 bar, i then disconnected the condensate pipe and sat it in a bucket. i left it like that overnight, in the morning the boiler pressure was at zero, and the bucket was one third full of water, is this a secondary heat exchanger issue or can anyone advise.

i called british gas to get their one off repair deal, the guy came out and said he can't touch my boiler as it's not on their service list.

my boiler is a 3 year old ferroli domicondens f 28
robert, November 2013
new secondary heat exchanger fitted, it was leaking and losing the water through the condensate pipe

robert, January 2014