Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

Changed grill element cooling fan stays on? ?

I own a Moffat MFS 620X. The grill element failed which I changed. When I powered the cooker on again I noticed the cooling fan is on and will not turn off. As you probably know there is a thermostat on one of the holding nuts of the element. I thought I had damaged this switch so I replaced it, but the fan remains on. Any ideas what the problem may be.
Ken, February 2014
Sounds like incorrectly re wired after grill replacement. The stat for the cooling fan is the only switching mechanism for it so when the stat is cold it should be open circuit and no other way the fan can be fed. trace the wire back from the fan and make sure it is on one side of the stat and not on a grill terminal.

Kenjo, February 2014
link Click here to see other fixes for Moffat.