John asked ... Scantronix 9450 box stuck shut?    |    Pekaye asked ... Clutch Cable change?    |    Richard asked ... Mountfield SP414 mower, revs too high?    |    Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Click here to ask your question

How can I get my water and heating to work?

I have a ideal logic combi 24 boiler with a fault showing code f1, I know this is the pressure, I've turned valves but nothing have happened the pressure is still nearly 0, I've also checked to see if there have been any leaks from radiators but nothing can you help me?
Jade, February 2014
you use the filling loop to pressurise the system to around 1.1bar.goes from the 15mm cold water feed to the 22mm CH return pipe.type filling loop in to youtube and watch some of the videos

Mike, February 2014