Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

has the central heating pump gone no clock?

power to the spur dowmstairs keeps blowing the 3 amp fuse no clock or power to boiler in the kitchen has the pump in the loft seized up
dave, March 2014
If it blows immediately on power up the pump is likely to be faulty,if it blows after a delay it could have seized,to check remove the large silver screw at the back of pump [a small amount of water will come out ] and insert a screw driver into the end of the shaft and twist to see if is free

toptrish, March 2014