Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Click here to ask your question

has the central heating pump gone no clock?

power to the spur dowmstairs keeps blowing the 3 amp fuse no clock or power to boiler in the kitchen has the pump in the loft seized up
dave, March 2014
If it blows immediately on power up the pump is likely to be faulty,if it blows after a delay it could have seized,to check remove the large silver screw at the back of pump [a small amount of water will come out ] and insert a screw driver into the end of the shaft and twist to see if is free