dave s asked ... Transmission not working?    |    Tom asked ... Replace rear right door upper right latch cable - high roof?    |    ian asked ... Vaillant timeswitch 150 analogue unit (clock stopped?    |    Art Cour asked ... How do I get engine cowling off to find gas leaking?    |    liz asked ... Changing a belt?    |    Click here to ask your question

potterton boiler fires up then gos off with loud banging from the pipes?

potterton suprema red light is flashing but boiler fires up then goes off afther 30 seconds can any body help
rickie dhaliwal, December 2006
Hi
My combi boiler works fine in the summer but in the winter it fails to come on in the morning and the red reset button is lit. I press this and it is fine again. I am convinced it only does this when the temperatures are very low ie freezing point approx. It is in the garage. Help!
Thanks

holmfirthdavid@aol.com, March 2008
Yes its definitely caused by the pump not running or maybe only running intermittently. My pump had a loose connection to it and so it worked sometimes and sometimes didn't. Having re-fitted the wires into the connector block it ran fine and almost silent boiler again.
You can check for this easily by gently moving the cable where it goes into the pump connector box - if the pump starts and stops - thats the problem.
If that doesn't cure it - try gently tapping the pump with a soft hammer to just shake it into life.
If that fails, there is sometimes a little plastic cap at the back end of the pump - undo this and check inside if there is a square or slotted shaft inside. In either case, try moving the shaft carefully with the tip of a screwdriver to get the pump started.
If that is unsuccessful, sorry - new pump.

Ade, December 2006
sounds like the pump has packed up therefore the boiler is overheating

stu, December 2006
link Click here to see other fixes for Potterton.