katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Mark asked ... Oven door removal?    |    Click here to ask your question

pilot light wont stay on?

we have a glow worm space saver mk 2 and the pilot light has turned itself of and now we cant get it to stay on again so system wont start. any ideas what this could be?????? pls help its coldddddddddd.
ian, December 2006
Just fixed mine.

blocksge in pilot injector.

SWITCH GAS OFF AT MAIN

remove nut at base of pilot tube ang remove injector.

strip a piece of electrical flex and use a single strand of wire as a pricker and look through to make sue tube clear, reassemble making sure nut leaktight.

switch gas back on and try.

if the imjector is blocked thermocouple dosnt get hot enough

NO LIABILITY TAKEN IF YOU FOLLOW THIS PROCEDURE!!!

martin, December 2006
got the same problem

Sounds like thermocouple or valve block

these sites may be of interest.

http://www.glow-worm.co.uk/service/documentation_noncurrent.asp

http://www.keeptheheaton.com/acatalog/glowworm.html?gclid=CI73ydn2mYkCFQJPQgodnHkoUQ

jmc

Martin, December 2006