Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

HELP! Vaillant combi inop. No Spark VCW GB 242EH?

I have a Vaillant Combi VCW GB 242 EH and it will not ignite,
No Spark, No Gas (No Voltage to Ignition Module for Ignition leads nor voltage to gas valve) Fan runs when Heating switched on, have replaced Flame & Spark Supervision board also replaced main elctronics board & pump replaced (partially siezed, turning slowly) Still it doesn't go! Really need some help or info with this.
Any more info required send me a message.
Thank you in advance for any replys

Paul
Paul, December 2006
Just thought I'd say a big thanx to Gasaid.co.uk & Jaz. New Air pressure Switch fixed it :o)

Paul, December 2006
Try the Air Pressure Switch. It needs to prove in order to send signal to ignition sequence and gas valve. Good Luck...

Jaz, December 2006
Try the APS.... Has been problematic on a lot of the appliances as the first round of HUBA switches kept breaking their limits.

GasAid.co.uk, December 2006
link Click here to see other fixes for Vaillant.