Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Roberta asked ... DW5080?    |    Click here to ask your question

Ideal isar 30 combi/boiler?

boiler trips out on F/l display
On resetting usually takes 3 attempts to fire up
Fault occurs between every 1 to 5 days
Graham B, September 2015
LF
Multiple causes
Could be
Ignition electrode 173528
Detection electrode 173529
Detection lead 173512
Spark generator 173538
Condensate trap 174244
Flueing issues
Gas supply problems
Wiring harness problems
Or maybe even the pcb

The list of possible causes for LF are numerous
& each one requires a different strategy to test it

The boiler manual goes into great detail as to how try to test each component
Provided you have a multimeter a flue gas analyser & a manometer

Q, September 2015