Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

aeg sensorlogic tripping fusebox?

machine working fine after 12 years now tripping rcd could this be the heater element /pump ? earth fault ? i am an ex mechanic but no electrician.
michael brett, December 2019
There are several conditions that can create the Earth leakage you are describing. With your AEG I'd suggest you pull it out and check for water leaks. Remove the side panels so you can see the workings underneath, pay particular attention to the water hose that supplys the bottom spray bar as these can split or weep, dripping water on to the heater element and causing the RCD trip condition. With the panels removed, and power isolated, deal with any moisture you find and let everything dry out thoroughly overnight. Run the machine and see if things have improved enough not to trip the RCD, then keep an eye out for leaks when running to see if you can spot any.. repair as nescesary.

Rupert, December 2019