Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    Click here to ask your question

fault codes on hoover fridge/freezer?

i need to know what the error codes 1 and 7 mean on model hca394fkpw
mark, January 2005
Da flashing on fridge freezer ok on panel

Lorraine, September 2021
ERR.01 Communication error between the two modules for more than one minute

ERR.02 Refigerator Evaporator Probe Open

ERR.03 Refigerator Evaporator Probe short circuit

4&5 not used

ERR.06 Problem in main module memory.

ERR.07 Freezer Evaporator Probe Open

ERR.08 Freezer Evaporator Probe short circuit

ERR.09 The fault symbol is displayed if the dispenser switch is pressed and after 10 Seconds the number of impulses counted is less than or equal to 30 (e.g. faulty litre counter). When the switch is released that fault test procedure will restart from the beginning.

Alan T, July 2008
link Click here to see other fixes for Hoover.