3 hours ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

I need to fix my combi boiler - Vaillant 242 E?

Whenever the boiler goes to light it blows the E2 fuse - Any ideas as I do not have the light up sequence and it blows almost immediately.
Karl M., January 2007
or alternatively use a multimeter

paul, January 2007
one possible cause is that you have a problem with the main gas valve.. or a short on the cables to gas valve. best way to check is to disconnect cables to valve usually two push on spade connectors.. first isolate the boiler of all electrical supply. making sure that all cables are safe and not touching any boiler parts turn supply back on.try to relight. it wont but if fuse doesnt blow that is problem. another possible cause is if it has electronic ignition you have a problem with your high tension ignition coil. apply same procedure as above.

debra, January 2007