Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

how can i fix ferroli combi 77ff?

The system pressure is not stable and i am having to top system up regularly. There is no obvious leak in system.
neil king, March 2007
Sounds like it could be the automatic air vent that releases air out of the system. When you top up a system and it then heats up dissolved oxygen is then driven off this is then released by the vent (dropping your system presure )when a system is first filled up. This can go on for a few weeks but will then setle down when all the oxgen is driven off.Other than that try the ferroli helpline (technical option )for installers they are very helpfull. Hope this is of some use

Tony, March 2007
check prv or expansion vessel faulty

hi-spec plumbing, March 2007