3 hours ago Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Click here to ask your question

How can i fix my VAILLANT BOILER?

I have no hot water or heating,there is a green light on. In temp box there is F22 showing, how do i fix it.
Jason, April 2007
check you have pressure in the boiler if you have the chances are the pump is stuck

markbb, April 2007
How do i fill my pressure gauge up, which pipe is it..

Jason., April 2007
f22 means boiler needs water, is the pressure gauge reading below 0.7 bar. if so it needs refilling to 1.5 bar

hi-spec plumbing, April 2007