Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

why has my britony 80&100 ?

why has my britony combi 80&100 just started to have water coming out of the over flo pipe that go,es out side
chris, May 2007
Have you recently had to top up the system pressure? If you have, have you closed the filling loop fully?

Could also be pressure gone in expansion vessel or expansion tube blocked? Does the pressure rise to 3bar before the water starts to leak out? If it does, either of the above faults may be present.

A competent (CORGI eng) will be able to check the expansion vessel for you. They're usually charged up with air to a pressure of 1 bar. If on testing he gets water out of the vessel, it needs replacing. If he gets nothing at all out of it(water or air) it needs repressurizing. If he gets air from it, its probably a blocked expansion tube.

Baz (CORGI Eng), May 2007
prv is leaking

hi-spec plumbing, May 2007