1 hour ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

replacing bathroom ceiling light?

I am replacing the old bathroom light fitting.When i came to take it off there are 3 grey wires coming out of the ceiling .
None of then are marked but 2 are wrapped together and
are connected to one connction and the is a single grey wire
fitted to the other connection.

My new ceiling light has a live and neutral marked on it.
Are the 2 grey wires wrapped togrther to go into the live connection
or is this correct
Gerry Soye, Dublin, September 2007
the other answer on here is wrong .disregard it. lights should not be switched by the neutral .if you have no earth you should use a class 2 fitting and get someone to investigate where the earth has gone

john, November 2007
Gerry ...... sounds like the two wrapped together are the live and the single will be the neutral from the switch. Where's the earth? If you blow the lighting fuse when you switch on then it's wired up the other way round, where you have a switched live instead of a switched neutral.