Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Roberta asked ... DW5080?    |    Click here to ask your question

glow worm 50?

i have glowworm micron 50works ok when it calls for hot water but will not always fire up for central heating can you help have wirless room stat which re programs ok and says calling for heat when boiler does fire up will run till reaches temp ok but then will not restart it seems to want tobe cold before it will run again it did have new pcb fitted but that was about three years ago they had a fault with them on the origanal ones but glow would not admit it thanks pete
peter warwick woodworkpete67@aol.com, September 2007
Got a new thermister £13.00
IT WORKS !!
Boiler okay,heating okay
Heppy Days

Martin, November 2007
Hello
I have same problem as you.
I have changed PCB and not cured it.
Reading all the other posts i now think its the Thermistor, they are advertised at around £10 +VAT +p&p.
I am going to try this,will post result.
Is yours connected to a gledhill ?

Martin, October 2007