2 hours ago Dave asked ... Repair kettle lid?    |    Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Click here to ask your question

vaillant open vent ecotec plus 418 fault 28?

boiler fired up when first turned on then turned it off when turned on again no egnition two codes come up s98 and f28
jonnie, November 2007
Quote from Service manual (available as pdf from vailliant site)
Fault 28 - Fault in the gas supply such as:-Gas meter or Gas pressure detector defective. Air in gas, gas pressure too low. Fire detection tap has disengaged. Fault in the gas valve, wrong gas setting, Igniter (ignition transformer, ignition cable, ignition plug) defective. Ionisation currnent stopped (cable, electrode), Faulty earthing in appliance, electronics defective.

S98Flow/Return sensor check is running. demand (DHW or Heating) is blocked.

Peter kay, December 2007