Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

I have a Vaillant turbomax VUW 242E?

I have a valliant turbomax vuw 242e... The problem is that the pressure is reaching 3 bar.... I have tried bleeding water out of the radiators , this causs it to drop but it the climbes again.. could it be water in the expansion vessell?
Lont, December 2007
Check your expansion vessel, try turning your cold water inlet valve off - see if it rises then, if yes then there is a leak on the domestic heat exchanger, normally if this is the case then the pressure would continue to rise all the time.

Big A, December 2007
Thanks... I have checked the loop and it isnt drawing any water into the boiler.

lont, December 2007
First I would disconnect the filling loop in case it is continuously allowing fresh water into the boiler.

John, December 2007
link Click here to see other fixes for Vaillant VUW 242E.