Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

How can I get Hot water?

Does anyone know why my SIME FRIENDLY FORMAT 80E combi boiler will only give us hot water while the central heating is on?
If the heating is off, then water is cold.
malcolm, March 2008
the divertor valve is not working correctly you do not stay weather boiler comes on when you have hot water only on if not it could be the diaghram requires replacing only if it does the divertor valve will require replacing you can fit service kit but valve not expensive

tony, March 2008
the divertor valve is not working correctly you do not stay weather boiler comes on when you have hot water only on if not it could be the diaghram requires replacing only if it does the divertor valve will require replacing you can fit service kit but valve not expensive

tony, March 2008