katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Mark asked ... Oven door removal?    |    Click here to ask your question

Power failure on Ideal Combi Boiler?

Have had a power failure at the boiler. All the boiler lights are off and house circuit breakers are all fine. Have checked that there is voltage into back off the power control panel (on/off Switch panel) but have run out of ideas other than to replace the panel. Any suggestions?
Mark, March 2008
And was there voltage there? Or is it dead?

If it is dead, have you tried the fuse at your 3amp spur (assumeing you have one).....as it says on the tin, only use a 3amp fuse!

If there is power to the back of the unit, could be your pcb is dead, only problem is, if it blew like that, your pump or fan motor or gasvalve solenoid may be gone also and they would be what blew the board!

More info....

T, March 2008