Baxi Bermuda 2 inset fire?

I have a Baxi Bermuda 2 inset fire only, ( no back boiler ) I press the button to light it, I hear it sparking for a few seconds then it stops but does not light ? any advice ?


done

Have CH+HW but HW alone is intermitant?

I have Potterton Ep2000 and Baxi Bermuda boiler with two valves a pump and a HW tank . I have CH but no HW or it runs intermittently I fitted a new thermostat to cylinder but this didn't work , whe ... more


Baxi Bermuda back boiler 551?

how to fix the furnace(no flame), the pilot light is on,the timer and thermostat are on


the heater will not come on?

ih i have a baxi bermuda 50/5 inset but the light will not come on for the heateing will not work but the gree light comes on for to heat the water.


Baxi Bermuda 522?

There is a clicking, cracking noise ( it is not loud) from the back of the boiler when it is running, boiler starts & stops ok.


Baxi GF Super Fireglow light?

Can anyone tell me how to replace a lampholder for the Fireglow bulbs on a Baxi Bermuda GF Super boiler/fire assembly. (Maybe LFE3 is the factory model number for this boiler). It seems a simple job ... more


baxi bermuda boiler, over 20 + years old?

When my CH switches on, on the timer my hot water turns on as well even though it is switched off, why does it do this?


done

baxi bermuda 51/5 ?

I have had a new baxii Bermuda 51/5 back burner installed with a new fire over a year ago problem is my header tank keeps overflowing . I have replaced the ballcock and the problem still persists . An ... more


How can I fix ?

Baxi Bermuda inset 3 has no electrical power after programmer


how can i fix baxi bermuda vp gas fire?

spark generater is ok but gas is intermitten upto 15 min or not at all some days


baxi bermuda 522?

still getting hot water & heating, but is making clanging noises ,more so when its just the water


Baxi Bermuda 552 Pilot Light?

I can light my pilot light an the burner lights. It goes through it's burn cycle and switches off. When this happens, the solenoid clunks and the pilot light goes out. Any ideas?


baxi bermuda 551 b?

burner lights and burns ok with boiler front cover off as soon as you replace front cover the flames come out from under the front cover i have smoked the flue and is ok can you help thanks john


done

Baxi Bermuda Insert 3 fire?

my fire will not light the pilot light will light but after sequence will just go out and fire will not light. also if it does light the fire will go for about 5 minutes then just switch off.


Baxi Bermuda Inset 2 boiler 50/4?

Pilot light regularly goes out, and have to manually light again, sometimes takes a couple of goes, I think the pilot light sometimes goes out just as the boiler is about to fire up. Clean and service ... more


Baxi Bermuda 3 (50/5) back boiler - orange pilot light on, won't reset?

I have the above boiler and set the system to low whilst I was away over Christmas. Orange pilot light is now on and it won't reset; fire not working either. PCB replaced a few months ago...help!


error code E131 on my baxi bermuda ?

what does E131 fault mean on my new baxi bermuda back boiler


What wrong with my boiler?

I have a baxi Bermuda w2. Hot water working but rads are not. Any suggestions plz!


done

bermuda baxi boiler 401?

my system is now not working - the pilot light will not fire up and i think my pump needs changing - how much will this cost and for a service also.


done

Baxi Bermuda 5 does not fire up?

My very old Baxi Bermuda 5 will not fire up even though the pilot light is good and constant, it just refused to fire up but working well the previous day. I'm pretty sure the problem is the solenoid ... more