4 hours ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

baix combi?

in ch and dhw mode;
boiler star, pump start working, but when boiler demand for fan to ingage, fan doesn't come on, I cheched fan Terminals, there is no power there.
I cheched the micro switched for DHW and CH both make the connection, but fan doesnt come on.
David, July 2008
first check the boiler and hi limit stats are ok, then check the aps isnt faulty (stuck in nc position)

if not, may well be a pcb issue.....my money is on the aps