David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    John asked ... How can I mend my binatone veva 1210 handset?    |    Click here to ask your question

FIREBIRD 90 INSTALLATION?

Just installed firebird 90 which I got from a friend which was just serviced before we removed it from his house.I removed my own warmflow which sprang a leak in the boiler.the pump(the one attached to the water supply) on the old one was faulty so I had a new one to fit.The arrow on the old pump was facing towards the boiler but the new one was facing the other way so I turned it upside down to face it the same way the old came out.I started the burner up and she fired but after it heated up she cut out.have bled all the system.the rads did not heat up,so I checked the exspansion tank and it was filling up and over flowing into main tank.the lower pipe in the tank was warm so I presume the pump was sending the water to tank and not the rads.I removed the pump and turned it around the other way and this stopped the overflow but still no rads heated up.is the pump in the right direction or do I have a air lock some where which caused the overflow?
Noel, August 2008
Thanks for your answer.much obliged.will get it recified.

Noel, August 2008
if the pump is on the 'return' side of the boiler (the lower pipe) the arrow points to the boiler, if it is on the 'flow' side (the upper pipe) it should point away from the boiler..........

but I think your problem is you have airlocked your system when re-filling it and best advice is get your plumber out to unlock it

T, August 2008