Freya asked ... Frister & Rossman Cub7 Sewing Machine?    |    katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Click here to ask your question

Glow-worm 30CxI?

i have a Glow-worm 30CxI combi boiler and i need to drain the system could you give me any help thx
karl, October 2008
Amateur advice, so beware.

Do not be tempted to use the pressure relief valve to drain the boiler; you may get debris in the valve which will cause problems.

The way I have done this in the past is to turn off the electrical power, let the system cool and then drain boiler, radiators and all by using the drain cock of the heating system, usually to be found at the lowest point. Failing that, use the lowest radiator's bleed valve.

When you come to refill the system, use the built-in filling loop (blue knob underneath the boiler), and use it carefully: people say that it's a bit fragile. Pressurise to 1.0 bar.

Jonathan, October 2008
please contact : technical@glow-worm.co.uk

andy, October 2008