4 hours ago Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Roberta asked ... DW5080?    |    Dave asked ... Toilet Push Button not flushing properly?    |    Click here to ask your question

Hoover HNF7167 water not emptying. I first thought it was pump, but?

Hoover HNF7167 water not emptying. I first thought it was pump, but tested it and it works. Put it back on and now nothing works, just a faint glimmer behind buttons. Has anybody any idea what's wrong? (Could it possibly be control pcb?) If so where can I get spare parts?
Rileysgrandad, January 2009
I've had the same problem with the terminal connectors shorting out against each other where they connect onto the drain pump.
At present everything else works except the drain pump. I checked the pump by running a cable straight from the socket onto the pump, using spade connectors. Ran okay.
I put the machine on a drain cycle and checked for voltage at the pcb connections. Not got any voltage. I checked the cables for continuity and that was okay.
Looks like I might need a new pcb unless I can find a fuse blown on the board.

Ian, January 2012
have just had the same problem and found that the 2 terminals on to the pump have been shorting out. i am now not getting the 240v to the pump and think the circuit board is now blown

kevin, March 2009