Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

fisher and paykel not draining, pump not blocked?

fisher and paykel gw 509 is not draining, I've checked the pump and it's not blocked what to do next thanks
Nick, March 2009
When you put it on final spin & press start can you hear the pump humming? If so it is trying to go but something is stopping it. If it doesn't even give any sound then you need to check the pump copper winding with an ohm meter. Resistance should be 33 ohms. If pump reading is ok then you may have a fault in the controller & no power is being delivered to drive the pump.

Lincoln Appliance NZ, March 2009
link Click here to see other fixes for Fisher & Paykel GW509.