Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

saunier duval old boiler?

we have a SD combi boiler and the heating is working fine but the hot water only works when the heating is ON - can anyone help? this is annoying when weather is good and expensive
Nat, March 2009
The water valve diaphragm has a split in it, and the water flow cannot move the switch, If you move the lever on the front to the left and back again while the tap is running it may work, but only until the tap is shut. Replacing the diaphragm is the answer,simple low cost fault.

Bendan, April 2009