Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Sharma asked ... Replacing pin for belt guard Ranch King Pro 14AT818H205?    |    Click here to ask your question

boiler not firing ?

hi
my regular conventional halstead hero 40 boiler wont fire up there is sometimes a dim light as if it is really trying to ignite. about 4 weeks ago i noticed that it was turning itself off, so i put in salamandar sludge remover about 3 weeks ago, and yesterday it wouldnt come on at all.
there is no heating or hot water and due to finances i wouldnt be able to get anyone to look at it till the end of the month and even then it would depend on the outlay.
i would be grateful for any information and advise given in the meantime.
cheers
kathydon, April 2009
Have a look in the combustion chamber. The baffles have a nasty tendancy to corrode on these boilers and can fall onto the ignition electrodes.

M, April 2009
I think that your sludge remover has worked too well - the chances are it has blocked up a sensor somewhere which is impeding water flow. It does need a service, I fear.

John, April 2009