2 hours ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

time length of riello burner to ignite?

Firebird boiler has riello burner ,When you call for heating or hot water fan motor runs but burner can take up to ten minutes to ignite is this correct operration.
m.elliott, May 2009
You Don't say whether its a Riello R40, or the newer RDB, but the cause is usually the same, Repalce the Photo resistor, this in 90% of cases is the cause of a long pre purge on a Riello burner

www.elanar.co.uk, May 2009