wall hung boiler and aga problems?

Oil boiler is wall hung, aga lower level system has a oil lifter, if we lifted the oil tank would i be able to remove the lifter as is in the loft and smells.
Thanks
Dan
Dan, May 2009
If the Boiler is less than 3.5 Metres from the BOTTOM of the oil tank, you could fit a Tiger loop on a separate oil supply from the tank, as long as the bottom of the oil tank is above the Oil Control Valve on the AGA, AND it is fed by a separate pipe from the tank all should be well

www.elanar.co.uk, May 2009