Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Click here to ask your question

HOW CAN I FIX MY COMBI BOILER, SIME FRIENDLY FORMAT 80E?

THE WATER RUNS OUT OF THE BOILER OVERFLOW
RICHARD WILSON, January 2006
hi, any body ther to help me how to fix the problem, central heating work but hot water no work, tape water put on hot water com after 5 or 10 2nd later water get cold, 4 months go put new boiler clean the radioter but no power flush, boiler make biasi

faruk, July 2010
BRITISH GAS DO AN EXCELLENT SERVICE BASICALLY 16 PER MONTH THATS ALL PARTS LABOUR AND CALL OUT. BARGAIN I WOULD SAY

clayre o'rourke, February 2006
hi the pressure on your boiler should be about 1 .5 bar, the safety valve will lift at about 3 bar if this has gone over 3 bar then that is why the safety valve outlet is leaking, the safety valve should close when the pressure is reduced to a very low pressure.i would switch off the boiler and drop the pressure by turning the red safety valve head [knob] till the pressure is about between 0 and .5 barthen fill up the system to 1.3 bar and switch on the boiler.if its still leaking.fit a new safety valve about £15.00, to fit is very simple the baes of the valve has on its side a very small allen headed grub screw, undo this, after of coures turning of the boiler and releaseing the pressure,then it will pull out, it has an o ring to seal the joint,it takes a good pull to get it out but it wll come,it is not screwed it. ps twisting the safety valve head while under pressure can some times clear any dirt under the safety valve seat.DO NOT MESS WITH GAS. bob.

bob roberts, February 2006
link Click here to see other fixes for Sime.