Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

how can i fix the water constantly dripping from thepipe outside the back d?

halstead boiler, back from holiday put on the central heating,pressure gage went up to 3, found a rad not working checked the thermostate on the rad and it had gone so took it off and put on the heating again and the pressure went down to normal 1 to 1.5 and the rad worked, but the water constantly drips from the pipe out side the back door, how can i stop this water from flowing?
caroline, October 2009
The pressure release valve (PRV) usually lifts at 3 bar, but the trouble is, they rarely seal themselves down again - so its replacement is the only real cure.

John, October 2009