Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

worcester bosch 240 pressure on 3 bars?

does anybody no how to release the pressure to get it back down to 1.5
john, October 2009
Try to find the central heating drain point outside (below floor level on the outside wall, with a square head on the screw part), open that and let the pressure fall. If the pressure continues to rise, your filling loop is not properly closed, or (rarely) the dhw heat exchanger has a hole between the primary and secondary water and would need replaced.

Iain, October 2009
Bleed water off from the radiators - it takes a while, you may need to lose a couple of pints but its the most boiler friendly way!

John, October 2009
link Click here to see other fixes for Worcester.