Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

Hygena Diplomat Softline ADP0500 grill not working?

I have a Hygena Diplomat Softline ADP0500 and the grill does not work, is there a reset switch located anywhere. There is no gas getting to it either
ANdrea, January 2010
THANKS GLEN I have the same problem on a Diplomat adp0504.I will try your suggestion. Bernie (retired plumber)

Bernie (retired Plumber), November 2010
how do i reset it

anil, September 2010
yes, there is a thermal cut out switch.
Release appliance from housing.
unscrew top /rear panel securing screws.
Ease panel backwards, remove both fan leads and lift panel clear.
Remove 2 screws securing thermal cutout switch to inner grillcover and replace.

glen, May 2010
link Click here to see other fixes for Diplomat.